Technical Information / Downloads

Thermaflow Range Technical Overview :

pdf TH_series_technical_download.pdf

pdf TSL_series_technical_download.pdf

Thermaflow Instructions for use Installation and Servicing :
pdf TH_series_instructions.pdf

pdf TSL140-170_instructions.pdf

pdf TSL210-250-330_instructions.pdf
Off Peak Control Settings :
pdf off_peak_control_settings.pdf (England)

pdf off_peak_control_settings.pdf (Scotland)

 

model
TH9 / 210U TH9 / 250U TH9 / 330U TH12 / 210U TH12 / 250U TH12 / 330U
Height (mm) 1640 1940 1970 1640 1940 1970
Width (mm) 590 590 650 590 590 650
Depth (mm) 740 740 790 740 740 790
Capacity (L) 210 250 330 210 250 330
Max system capacity (L) @ 10°C 310 360 470 310 360 470
Lift weight (kg) 60 65 75 60 65 75
Total weight (kg) 70 77 85 70 77 85
Weight when full (kg) 270 315 405 270 315 405
Output heating ¹ (kW) 10 11 13 13 14 16
DHW flow rate @ 40°C t (L/min) 30 30 30 30 30 30
DHW available for use (L) 250 300 390 260 310 400
¹ Energy output available with store fully energised and power on to boiler
 
APPLICATION Flat 1/2 Bed
1 Bath / 1 Shower
House 1/2 Bed
1 Bath / 1 Shower
House 2/3 Bed
1 Bath / 1 Shower
Flat 2/3 Bed
1 Bath / 1 Shower
House 2/3 Bed
1 Bath / 1 Shower
House 3/4 Bed
1 Bath / 1 Shower
Heat up 75° t (mins) 162.5 192.5 255 130 154 204
Re-heat 70% (mins) 113.75 134.75 178.5 91 108 143
Min water supply pressure (bar) 0.8
(80KPA)
0.8
(80KPA)
0.8
(80KPA)
0.8
(80KPA)
0.8
(80KPA)
0.8
(80KPA)
Max cold supply pressure 4
(400KPA)
4
(400KPA)
4
(400KPA)
4
(400KPA)
4
(400KPA)
4
(400KPA)
Max system pressure - Primary (bar) 3
(300KPA)
3
(300KPA)
3
(300KPA)
3
(300KPA)
3
(300KPA)
3
(300KPA)
Max heating system content
(excluding store volume) - Primary (L)
110 130 150 110 130 150
Expansion vessel
charge pressure
Primary (bar)
1.5
(150KPA)
1.5
(150KPA)
1.5
(150KPA)
1.5
(150KPA)
1.5
(150KPA)
1.5
(150KPA)
Expansion vessel
charge pressure - Secondary (bar)
3.5
(350KPA)
3.5
(350KPA)
3.5
(350KPA)
3.5
(350KPA)
3.5
(350KPA)
3.5
(350KPA)
Safety Valve - Preset (bar) 3
(300KPA)
3
(300KPA)
3
(300KPA)
3
(300KPA)
3
(300KPA)
3
(300KPA)
Connections Compression Compression Compression Compression Compression Compression
CH - Flow & Return (mm) 22 22 22 22 22 22
Domestic cold inlet (mm) 22 22 22 22 22 22
Domestic hot outlet (mm) 22 22 22 22 22 22
Safety release valve (mm) 15 15 15 15 15 15
ELECTRICAL SUPPLY OFF-PEAK
Boiler power rating (kW) 9 9 9 12 12 12
Rated voltage - Single Phase~ (V) ~240 ~240 ~240 ~240 ~240 ~240
Rated current (A) 40 40 40 52 52 52
ELECTRICAL SUPPLY 24HR DOMESTIC
Total power consumption of controls (W) 190 190 190 190 190 190
Rated voltage - Single Phase~ (V) ~240 ~240 ~240 ~240 ~240 ~240
Rated current (A) 3 3 3 3 3 3
ENERGY EFFICIENCY RATING - 99.4%